HVAC Compatibility Tool from Intesis

Search and find the HVAC compatibility information you need.

There are 33 compatibilities

Introduce your Indoor or Outdoor Unit Reference (results are offered from the third typed character on):
error Check the entered characters for valid references
info
Shown compatible gateways are illustrative. Check your Indoor Unit and Outdoor Unit compatibility for further information.
Modbus

6 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin Altherma to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 16 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 64 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 4 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
KNX

8 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 16 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 64 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 4 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AW interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
· Up to 5 Indoor Units, 100 points
· Different connection depending on the AW brand:
 - Daikin, NIBE, Stiebel Eltron: Connected to Modbus TCP port
 - Atlantic, Baxi, Carrier, Ferroli, Gree, Haier, LG, Midea, Mitsubishi Heavy Industries: Connected to Modbus RTU port
REQUIRED ACCESSORY -
Daikin AC Domestic units to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin AC Domestic units to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
· 4 Binary Inputs
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
· 4 Binary Inputs
REQUIRED ACCESSORY -
BACnet

9 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin Altherma to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to BACnet MS/TP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 16 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 64 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 4 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AW interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
· Up to 5 Indoor Units, 100 points
· Different connection depending on the AW brand:
 - Daikin, NIBE, Stiebel Eltron: Connected to Modbus TCP port
 - Atlantic, Baxi, Carrier, Ferroli, Gree, Haier, LG, Midea, Mitsubishi Heavy Industries: Connected to Modbus RTU port
REQUIRED ACCESSORY -
Daikin AC Domestic units to BACnet IP/MSTP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet IP/MSTP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
MQTT

3 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 16 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 64 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 4 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
AC Cloud Control

2 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin AC Domestic units to AC Cloud Control (Wi-Fi) Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to AC Cloud Control (Wi-Fi) Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Home Automation

5 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 16 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 64 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Haier:
 - Up to 4 Indoor Units
 - Connected to AB or XY terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to Home Automation Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to Home Automation Interface
ADDITIONAL INFORMATION
 · Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -