HVAC Compatibility Tool from Intesis

Search and find the HVAC compatibility information you need.

Introduce your Indoor or Outdoor Unit Reference (results are offered from the third typed character on):
Check the characters entered for valid references
info
Shown compatible gateways are illustrative. Check your Indoor Unit and Outdoor Unit compatibility for further information.
Modbus

6 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin Altherma to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
KNX

7 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin AC Domestic units to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
· 4 Binary Inputs
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to KNX Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
· 4 Binary Inputs
REQUIRED ACCESSORY -
BACnet

7 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin AC Domestic units to BACnet MS/TP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet MS/TP and Modbus RTU Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to BACnet IP/MSTP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to BACnet IP/MSTP Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
AC Cloud Control

2 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Daikin AC Domestic units to AC Cloud Control (Wi-Fi) Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to AC Cloud Control (Wi-Fi) Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -
Home Automation

5 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Daikin AC Domestic units to Home Automation Interface
ADDITIONAL INFORMATION
· Up to 1 Indoor Unit
· Connected to S21 port
REQUIRED ACCESSORY -
Daikin VRV and Sky systems to Home Automation Interface
ADDITIONAL INFORMATION
 · Up to 1 Indoor Unit
· Connected to P1P2 terminals
REQUIRED ACCESSORY -