HVAC Compatibility Tool from Intesis

Search and find the HVAC compatibility information you need.

There are 16 compatibilities

Introduce your Indoor or Outdoor Unit Reference (results are offered from the third typed character on):
Check the characters entered for valid references
info
Shown compatible gateways are illustrative. Check your Indoor Unit and Outdoor Unit compatibility for further information.
Modbus

4 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Cascade Controller for Samsung Eco Heating Systems (EHS)
ADDITIONAL INFORMATION
· Up to 8 A2W Units
· Connected to R1R2 terminals
REQUIRED ACCESSORY -
KNX

3 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
BACnet

3 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
MQTT

3 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Home Automation

3 compatibilities

expand_more
ORDER CODE
PRODUCT DESCRIPTION
ADDITIONAL INFORMATION
REQUIRED ACCESSORY
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 64 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 64 Indoor Units, 64 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 64 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 100 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 64 Indoor Units, 32 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 64 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-AC brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
· Bosch:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 16 Indoor Units, 10 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 16 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 50 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 16 Indoor Units, 16 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
Intesis multi-brand AC interface with KNX, Serial and IP support
ADDITIONAL INFORMATION
Different features depending on the AC brand:
 · Bosch:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Daikin:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to F1F2 terminals
· Hisense:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Hitachi:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to AB terminals (H-Link)
· Midea:
 - Up to 4 Indoor Units
 - Connected to XYE terminals
· Mitsubishi Electric:
 - Up to 15 groups
 - Connected to Mitsubishi Electric Centralized Controller
· Panasonic:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to U1U2 terminals (P-Link)
· Samsung:
 - Up to 4 Indoor Units, 4 Outdoor Units
 - Connected to R1R2 terminals
REQUIRED ACCESSORY -
AC Cloud Control

No compatibilities

expand_more